With cable, length 1 m., 5 m. Or without cable.
RX level sensor with cable, plastic - used in Etatron automatic water treatment stations.
The sensor body with a diameter of 12 mm is made of epoxy resin filled with a transport electrolyte in the form of a gel, which guarantees operation at pressures up to 6 bar, supplied with a coaxial cable with a length of 1 to 5 m with a BNC connector.
Name | vendor code |
RX sensor 4 bar 60 ° C, wire 1 meter | AEL0002002 |
RX sensor 4 bar 60 ° C, wire 5 meters | AEL0002003 |
RX sensor 5.5 bar 60 ° C, without wire | AEL0004001 |
Wash and dry the electrode by shaking but not wiping, do not clean the probe, always use new buffers.
• Calibration: according to the application, about once a month.
• Continuous operation period is 1000 hours, after which it must be placed in KCL solution to restore sensitivity. It is recommended to install a filter in front of the flow housing.
• It is not possible to determine the sensor life externally.
If the readings are unstable, when the sensor reads slowly or intermittently, it is possible to restore normal operation by cleaning if there are deposits on the electrodes. To do this, it is necessary to clean metal surfaces with a material of little abrasion, such as toothpaste.
The sensor must not be allowed to dry out; during short-term storage, it may be placed in water.