EPHOTON photometric analyzers for measuring indicators: pH, RX, free and (or) total chlorine in water by the colorimetric method.
Name | vendor code |
EPHOTON PH-RX-CL Liquid AnalyzerFREE | QXB0003101 |
EPHOTON PH-RX-CL Liquid AnalyzerFREE /TOTAL | QXB0003201 |
The ePHOTON photometric system for 4 measured parameters (PH, Rx, free chlorine, total chlorine, temperature) includes:
1 PC. - Liquid analyzer ePHOTON PH-RX-CL FREE /TOTAL
1 PC. - pH level sensor
1 PC. - RedOx level sensor (OOP)
1 PC. - Temperature sensor PT100 PVC
1 PC. - OFF-LINE flow-through holder for pH, RedOx, PT100 sensors (including flow sensor)
1 PC. - Photometric measuring cell
3 pcs. - Peristaltic pump for supplying solutions for measuring
1 PC. - Set of solutions (refilling) DPD1 + buffer solution, DPD3; with a capacity of 1 liter. each
1 PC. - Mounting kit (including water analysis hoses and pre-filter with 150 micron mesh cartridge)
The ePHOTON photometric system for 3 measured parameters (PH, Rx, free chlorine, temperature) includes:
1 PC. - Liquid analyzer ePHOTON PH-RX-CL FREE
1 PC. - pH level sensor
1 PC. - RedOx level sensor (OOP)
1 PC. - Temperature sensor PT100 PVC
1 PC. - OFF-LINE flow-through holder for pH, RedOx, PT100 sensors (including flow sensor)
1 PC. - Photometric measuring cell
2 pcs. - Peristaltic pump for supplying solutions for measuring
1 PC. - Set of solutions (refilling) DPD1 + buffer solution, 1 liter capacity. each
1 PC. - Mounting kit (including water analysis hoses and pre-filter with 150 micron mesh cartridge)
Photometric measuring principle, colorimetric method with DPD. High-precision automatic chemical supply system for measuring with peristaltic pumps (1 or 2 channels). LED emitter at 520 nm, silicon photosensor. Measurement range: 0 - 5 ppm (mg /l). Resolution: ± 0.01 ppm. Accuracy: ± 2% of measured value, 98% repeatability. The frequency of control measurements is programmable from 3 to 120 minutes, in one minute increments. Step-by-step signaling of the lack of reagents (refilling): preliminary warning and complete blocking of work.
Thermal resistive measurement method. Sensor type NTC 100K at 25 ° C. Measurement range 0 - 50 ° C. Resolution ± 0.1 ° C. Accuracy ± 0.2 ° C, 99% repeatability.
Potentiometric measuring principle. Measurement range: 0-14 pH. Resolution: ± 0.01 pH. Accuracy: ± 1% of measured value, repeatability 98%. Asymmetry correction from 45 to 70 mV /pH. Input impedance 10 GΩ. Bias current
Potentiometric measuring principle. Measurement range: –1500 +1500 mV. Resolution: ± 1 mV. Accuracy ± 1% of measured value, repeatability 98%. Input impedance 10 GΩ. Bias current